MicroMag 2900/3900 Data File (Series 0016.002)
Remanence curves:  DCD

INSTRUMENT
Configuration                   VSM
Temperature control             None
Hardware version                0004
Software version                01/29/2013
Units of measure                Hybrid SI
Temperature in                  Kelvin

SAMPLE
Mass                            N/A
Volume                          N/A
Demagnetizing factor            N/A

SETTINGS
Field range                     N/A
Field (command)                 N/A
Moment range                   +1.000000E-03
Averaging time                 +100.0000E-03
Temperature (command)           N/A
Tmprtr difference correction    No
Orientation                     0.000000E+00
Vibration amplitude             1.0
Calibration factor             +5.102630E+00
Operating frequency            +83.00000E+00

MEASUREMENT
Description                    ""
Field (measured)                N/A
Temperature (measured)          N/A
Averages (completed)            N/A
Measured on                     09/04/2023  15:21
Elapsed time                   +98.28850E+00

PROCESSING
Background subtraction          No
Delta-m processing              No
Demagnetizing factor            No
Normalization                   No
Normalization factor            N/A
Offset (field)                  No
Offset (moment)                 No
Pole saturation                 No
Slope correction                No

VIEWPORT
Left                           -100.0000E-03
Right                          +100.0000E-03
Bottom                         -1.000000E-03
Top                            +1.000000E-03
Show X-axis?                    Yes
Show Y-axis?                    Yes

CHARACTERIZATION
Initial slope                   N/A
Saturation                      N/A
Remanence                      +39.72817E-06
Coercivity (direct)             N/A
Coercivity (remanent)          +23.19392E-03
S* (direct)                     N/A
S* (DCD)                       -216.9246E-03

SCRIPT
Include IRM?                    No
Include DCD?                    Yes
Include direct moment?          No
Demagnetize before measuring?   No
Field sequence                  Nonlinear
Initial (non-zero) field       +10.00000E-06
Final field                    +100.0000E-03
Number of points/curve          30
Pause at applied field         +100.0000E-03
Slew rate to applied field     +1.000000E+00
Averaging time                 +100.0000E-03
Saturating field               +100.0000E-03
Pause at saturating field      +1.000000E+00
Saturating field applied        Only once
Slew rate to saturating field  +1.000000E+00
Pause at zero field            +100.0000E-03
Slew rate to zero field        +1.000000E+00
Number of segments              1
Number of data                  30

Segment   Averaging      Initial        Field         Final                    Final 
 Number      Time         Field       Increment       Field         Pause      Index 
             (s)           (T)           (T)           (T)           (s)     
0000001,+100.0000E-03, 0.000000E+00,+10.00000E-06,-100.0000E-03,+100.0000E-03,0000030

                           
    Field       Remanence  
     (T)          (Am)    
+275.0002E-09,+39.72817E-06
-10.67153E-06,+39.72124E-06
-23.91111E-06,+39.68201E-06
-41.31654E-06,+39.66496E-06
-63.24236E-06,+39.64303E-06
-93.91598E-06,+39.61122E-06
-134.7021E-06,+39.58589E-06
-187.3063E-06,+39.55368E-06
-257.0021E-06,+39.49945E-06
-349.0612E-06,+39.43941E-06
-471.3993E-06,+39.34522E-06
-631.9411E-06,+39.21569E-06
-844.6841E-06,+38.94629E-06
-1.126216E-03,+38.57553E-06
-1.498220E-03,+37.97726E-06
-1.988460E-03,+37.13178E-06
-2.637794E-03,+35.92410E-06
-3.490933E-03,+34.27237E-06
-4.623428E-03,+32.07128E-06
-6.116799E-03,+29.13878E-06
-8.097105E-03,+25.27939E-06
-10.71158E-03,+20.33437E-06
-14.15690E-03,+14.08095E-06
-18.71415E-03,+6.483064E-06
-24.73437E-03,-2.229323E-06
-32.69313E-03,-11.62367E-06
-43.20859E-03,-20.84262E-06
-57.09255E-03,-28.94607E-06
-75.41522E-03,-35.23967E-06
-99.69603E-03,-39.66206E-06

MicroMag 2900/3900 Data File ends